Writing

Building science, on the record.

Field-tested notes on airflow, moisture, insulation systems, HVAC design, and the historic Gulf Coast homes that punish every shortcut. Written for homeowners, architects, and contractors who want the math behind the recommendation.

PHP Field Note Nº 021: The numbers came from the lumber. A to-scale drawing compares 2×4, 2×6, 2×10 and 2×12 framing depth with R-13, R-19, R-30 and R-38 batt thickness.

Field Note · Thermal Performance · R‑Value Series

R‑11, R‑13, R‑19, R‑30, R‑38. The numbers came from the lumber.

Batts were made to fit the framing, and the R‑value is what each batt measured at that thickness. Codes and blown-insulation labels then copied those numbers.

October 16, 2026 · Field Note Nº 021 · 7 min read
PHP Field Note Nº 020: A tougher finish is not a drying plan. A raised-floor layer diagram accompanies counts of Part 3, three figures, and nine sources.

Field Note · Raised Floors · Finishes

A tougher finish is not a drying plan.

Floor finishes, urethane, and vapor-control layers: what they protect, how they affect drying, and what to check before adding another coat.

September 28, 2026 · Field Note Nº 020 · 8 min read
PHP Field Note Nº 019: four floor-shape diagrams; four shapes, five figures, twelve sources.

Field Note · Raised Floors · Diagnosis

Read the floor before you repair it.

Cupping, crowning, buckling, and gapping: what the shape tells you, what it cannot prove, and when to put the sander away.

September 27, 2026 · Field Note Nº 019 · 10 min read
PHP Field Note Nº 018: Termites and spray foam. Ask about the concern, evidence, and alternatives.

Field Note · Insulation · Termite inspection

Termites and Spray Foam: What the Warnings Actually Prove

Choosing different insulation does not replace a termite-protection plan. A useful warning explains what an installation changes, what evidence supports the concern, and what the homeowner should do.

September 26, 2026 · Field Note Nº 018 · 8 min read
PHP Field Note Nº 017: Cold house, wet floor. The raised-floor article connects cool room air, humid crawlspace air, and a low-perm finish.

Field Note · Raised Floors · Gulf South Moisture

Cold house, wet floor.

Why raised wood floors in New Orleans cup in summer, and why the thermostat is part of the diagnosis.

September 25, 2026 · 10 min read · Wood floors, Part 1 of 4
PHP Field Note Nº 016: the R-value material test compared with a ceiling installation.

Field Note · Thermal Performance · Gulf South Enclosures

The R-value on the bag came from a hot plate. Your house is not a hot plate.

What the laboratory measures, what the label leaves to the installation, and how framing, moisture, and air control change the questions worth asking.

September 20, 2026 · 13 min read · Material ratings + installed performance
PHP Field Note Nº 4b plate: When air moves through insulation. Cream grid, black spine, gold headline emphasis, and the approved wall-circulation sketch.

Field Note · Insulation · Air Movement · Gulf South

When air moves through insulation.

Where convective looping matters, why installation quality counts, and what to fix.

September 20, 2026 · 7 min read · Insulation + air control
PHP Field Note Nº 015: Before you’re sold a $20,000 attic dehumidifier, check the perimeter first. Case summary: a $20,000-plus proposal, an open roof-to-wall perimeter, and condensation that stopped after the repair.

Field Note · Attic Moisture · Whole-House Diagnosis

Before you’re sold a $20,000 attic dehumidifier. Check the perimeter first.

Roofline foam was present, but the perimeter air seal was not. A New Orleans field case with repair photographs, the original hallway monitoring record, and verified technical context.

September 20, 2026 · Field Note Nº 015 · Attic moisture
Practical Home Performance — Nº 014 Field Note card reading: Dehumidify the attic, or fix the duct. With one round metal duct drawn twice, once inside a mastic-sealed foil-faced fiberglass jacket at 0.02 perm holding trapped water and rust staining, and once inside adhered closed-cell foam at 0.63 to 0.83 perm with outward drying arrows, and figures for an $18,750 mechanical path, an $8,400 enclosure path, and a $36,000 ten-year delta

Field Note · Cause, Not Symptom · Duct Moisture

Sweating Ducts in a Vented Attic: The $18,750 Machine and the $8,400 Enclosure Fix

Rigid metal ducts in the attic of a historic Algiers Point house kept sweating through a brand-new foil-faced wrap that had been mastic-sealed as tightly as anyone could seal it. One proposal added two ducted dehumidifiers, asked to seal off the attic ventilation, and carried a maintenance agreement to keep the warranty alive. The other took the jacket off and gave the water a way out. Latent load, nameplate capacity at real attic temperatures, and ten-year cost, computed.

September 13, 2026 · 49 min read · Duct moisture + assembly selection
Practical Home Performance — Nº 013 Field Note card with a figure showing a bottom-up section through a raised floor, where adhered sheet vinyl at 0.06 perm blocks the vapor drive rising through hardwood, a gapped board deck, and open-cell spray foam

Field Note · Moisture · Raised Floors

The physics were always going to win. Nobody ran the numbers.

Open-cell spray foam under sheet vinyl in an air-conditioned Gulf Coast raised house is a moisture trap. LSU and the USDA Forest Products Lab measured 20% subfloor moisture in exactly this assembly — and a five-line perm calculation would have flagged it before the first can was mixed.

September 7, 2026 · 14 min read · Moisture + raised floors
Practical Home Performance — Nº 012 Field Note card with a hand-drafted figure showing the same 1,500 square foot footprint drawn twice, once vented at 1:150 over bare ground and once at 1:1,500 with the ground covered

Field Note · Crawlspace Ventilation · Gulf South

Crawlspace ventilation by the numbers.

Vent area in the code is scaled to exposed dirt, not to drying. New Orleans summer air runs a 74.1 °F mean dew point and sits above 72 °F for 78.1% of hours, so there are no drying months to ventilate with — and a 1,500 square foot footprint needs 19 vents bare or 2 once the ground is covered.

August 22, 2026 · 28 min read · Code + psychrometrics
Practical Home Performance Field Note card on return plenum holes, showing a ductboard return plenum in a New Orleans attic with a large rectangular hole torn open in its side

Delivered capacity · Rail 03 · Losses

The return plenum hole: what one cut actually costs you.

Photographed holes in return plenums in New Orleans attics, then worked through the physics and reconciled it against Texas A&M psychrometric-room data. The answer is not in percentages of leakage — it is in delivered tons, which is the only number that matters to the room you are standing in.

August 25, 2026 · 11 min read · Delivered capacity + losses
Practical Home Performance — Nº 011 Field Note card in cream editorial layout with a serif headline 'One year, twelve houses, six ways to insulate a subfloor' and the running head 'DE / PHP FIELD NOTES · 11 / 26'

Field Note · Crawlspaces · Insulation · Gulf South

One year, twelve houses, six ways to insulate a subfloor.

Between October 2008 and October 2009, LSU AgCenter and USDA-FPL researchers instrumented twelve occupied Louisiana houses and monitored subfloor moisture for a full year. Six insulation systems went in. Two kept subfloors safely dry in every combination. Four did not. Sixteen years later, nothing bigger has been built on top of it.

September 8, 2026 · 12 min read · Crawlspace insulation + raised-floor moisture
Practical Home Performance — Nº 010 Field Note card with a hand-drafted figure of the same flexible duct drawn twice, once pulled taut between supports and once left slightly long and gathered into accordion waves, with KPI stacks reading plus or minus 2 percent taut, minus 36 percent air at 4 percent slack, and supports at 4 feet or less

Field Note · Delivered Capacity · Distribution · Gulf South

Four percent of slack costs you a third of your air

Pulled drum-tight, flexible duct moves air within about two percent of rigid sheet metal. Leave ten inches of extra length in a twenty-foot run and a six-inch branch drops from roughly 110 CFM to roughly 70 — a defect that is invisible from the attic hatch and forgiven by the design tables.

August 23, 2026 · 13 min read · Air distribution + Gulf South
Field Note Nº 009 card — “The night got cooler, not much wetter.” Overnight in New Orleans, temperature fell 12 °F while the dew point rose only 3 °F, sending relative humidity from 52 % to 87 %.

Field Note · Building Science 201 · Moisture · Gulf South

The dew point doesn't drop with the thermometer.

A cool Gulf South morning can read 87 % relative humidity without much more water in the air. Dew point is the number that tells you whether to open the window — and why the percentage is mostly telling you what time it is.

August 22, 2026 · 15 min read · Moisture + Gulf South
Practical Home Performance — Nº 008 Field Note card reading: Everybody blames the foam. The dryer was venting into the crawlspace. With figures for poly sheeting at 0.06 perm, closed cell at 0.74 perm, and zero drying paths

Field Note · Everybody Blames the Foam · Moisture Forensics

Everybody Blames the Foam. The Dryer Was Venting Into the Crawlspace.

A newly built New Orleans house lost flooring in a bedroom and a bathroom, and the closed-cell spray foam under the subfloor was assumed to be the cause. The record points somewhere else: an OSB panel sealed on both faces with no drying direction left, underlayment cut at every bottom plate, and a clothes dryer discharging roughly a gallon of water per load directly beneath the floor. Layer by layer, with perms.

August 21, 2026 · 14 min read · Vapor control + failure analysis
Practical Home Performance — Nº 007 Field Note card: three stud-bay cross-sections showing RESNET Grade I (full fill, six-sided contact), Grade II (minor gaps around an electrical box), and Grade III (interior-to-exterior void outlined in red), with color-coded grade bars underneath

Field Note · Insulation · RESNET · Louisiana

RESNET Grades I, II, and III: What They Actually Look Like in a Real Louisiana Attic.

A former RESNET-certified Energy Rater’s field notes on the standard nobody enforces the way they think they do. What Grade I actually requires, where the standard is generous, where installers get surprised, and why the pending Addendum D-202x is the wrong direction.

August 15, 2026 · 11 min read · Insulation + RESNET
Practical Home Performance — Nº 006 Field Note card showing a Gulf South crawlspace cross-section with closed-cell spray foam on the subfloor and a visible perimeter inspection strip on the sill plate

Field Note · Insulation · Gulf South

Closed-Cell Foam Under the Floor and Termites: Walking the Concerns, One by One.

A fair, plain-spoken walk through every objection raised about closed-cell foam under a crawlspace subfloor — which ones are real, which apply to fiberglass and no insulation just the same, and which single concern actually deserves the conversation.

August 6, 2026 · 10 min read · Insulation + termites
PHP Field Note Nº 005: When insulation gets wet. Cream graph-paper plate with black rail, gold italic emphasis and a hot-humid summer wall illustration.

Field Note · Building Science · Moisture

How Moisture Reduces R-Value

What the wet-insulation research actually shows, why the location of wetting matters, and how heat flow, moisture entry and drying interact in Gulf South homes.

Revised September 20, 2026 · Moisture + thermal performance
Practical Home Performance — Nº 003 Field Note card showing PAV pressure-plane depressurization diagram over a Gulf South house cross-section

Field Note · Building Science · Airflow

Powered Attic Ventilators: The Physics Behind the Ban

A whole-house pressure, moisture, and combustion-safety deep dive for Gulf South practitioners. Why one state banned them, ENERGY STAR refuses to certify them, and DOE doesn’t recommend them — the physics forces the conclusion.

August 2, 2026 · 12 min read · Physics + code
Practical Home Performance — Nº 004 Field Note card with southeast US map, Georgia highlighted amber, showing the state’s 2011 grid-connected PAV ban

Field Note · Code Policy · Deep South

Georgia Drew a Line in 2011. Fourteen Years Later, They’re Still the Only State That Has.

What one state’s quiet code amendment tells us about powered attic ventilators — and why the Gulf South still hasn’t caught up. The story of Section 403.10, the ENERGY STAR exclusion, and the solar carve-out.

August 2, 2026 · 7 min read · Deep South code policy
Practical Home Performance — Performance Path Paradox article card with blueprint-style house energy model comparing prescriptive vs performance path

Building Science 201 · Energy Code

The Performance Path Paradox: Why Building Professionals Have Overlooked a Compliance Option for Decades

Louisiana adopted the 2021 IRC and IECC in 2023, but most architects and code officials still default to prescriptive R-38. Guest author Mike Murphy, RESNET HERS Rater, on the compliance path hiding in plain sight.

August 2, 2026 · 11 min read · Guest: Mike Murphy
Practical Home Performance — Pressure Imbalances article card with Big Three drivers diagram

Building Science 201 · Airflow

Pressure Imbalances: The Invisible Energy Forces That Move Air Through Buildings

Wind, stack effect, and mechanical systems create pressure imbalances that drive airflow in every home. The building-science story behind the numbers.

March 21, 2026 · 9 min read